Alarms and stops
Morning shift, 06:00 to 14:00 · Carousel 1
Sample data
FrançaisStations out of production now
3
Active alarms
1
Total station stop time today
177 min
Of which unplanned
19 min
Active now
Station 7
Head sensor timeout
TIMEOUT_HEAD_SENSOR
Stopped, waiting for operator · for 4 min
Station 19
Not answering on the line
Offline · for 12 min
Station 15
Disabled for maintenance
Stopped by a manager from the app · since 08:10
Today’s stops by cause
Disabled for maintenance
158 min · Station 15
Link lost
12 min · Station 19
Head sensor timeout
4 min · Station 7
Filling timeout
3 min · Station 3
Grey: planned stop. Red: unplanned stop.
Long stops waiting for a cause
Threshold: 5 min
Whole carousel 1
From 09:31 to 09:43 · 12 min
Machines do not ask for the cause of a whole-carousel stop
Station 3
From 10:21 to 10:27 · 6 min
Suggested by the operator on the machine: Low or no gas
The final cause is the one saved by the shift leader; the operator’s suggestion stays stored with it.
Application alerts
Station 11
Drift: average of last 20 cycles +96 g
Above half of the overweight limit. 12 kg cylinder.
Suggestion: in-flight gas compensation
inflight_comp_g · 180 → 276 g
Station 4
Overweight on 3 of the last 10 cycles
The valve may not be closing well. Maintenance alert, no suggestion.
Event log
| Time | Station | Category | Event | Duration | Source | Priority |
|---|---|---|---|---|---|---|
| 10:44:12 | 7 | Alarm | Head sensor timeout ALARM 102 · TIMEOUT_HEAD_SENSOR | Instant | The device itself | Medium |
| 10:44:12 | 7 | State | Stopped after a fault, waiting for the operator STATE 3 · FAULT_LOCK · BEGIN | Active for 4 min | The device itself | — |
| 10:36:05 | 19 | Link | Device not answering on the line device_link_log | Active for 12 min | The gateway | Medium |
| 10:21:40 | 3 | Alarm | Filling timeout, weight at stop 17.42 kg ALARM 106 · TIMEOUT_FILL | 3 min | The device itself | Medium |
| 09:12:30 | 11 | Setting | Switch-to-slow-fill distance = 300 g CONFIG 1507 · fine_fill_offset_g | Instant | Remote | — |
| 08:10:02 | 15 | State | Disabled on purpose STATE 2 · DISABLED · BEGIN | Active for 2 h 38 min | Remote | — |
| 07:48:19 | 22 | Alarm | Operator report: leak at the filling head ALARM 109 · OPERATOR_REPORT · 1 | Instant | Operator on the machine | Medium |
| 06:02:11 | 11 | Calibration | Check with a test weight, deviation +10 g CALIB 3 · CALIB_CHECK | Instant | Operator on the machine | — |
| 06:00:03 | 11 | Power | Clock set, 2 s correction POWER 3 · CLOCK_SET | Instant | Remote | — |
9 events shown from a sample.